Items |
908449 FSK-254 Fluid Level Indicator with Level Switch List Price QUOTE
|
908587 HDA 4300 Pressure Transducer List Price QUOTE
|
922493 HDA 4300 Pressure Transducer List Price QUOTE
|
908586 HDA 4300 Pressure Transducer List Price QUOTE
|
909699 HDA 4300 Pressure Transducer List Price QUOTE
|
|||||
Description |
N/A
The pressure transmitter series HDA 4300 has a ceramic pressure measurement cell with a thick-film strain gauge which has been specially developed for measuring relative pressure in the low pressure range. The output signals 4 to 20 mA or 0 to 10 V allow connection of all HYDAC ELECTRONIC GMBH measurement and control devices as well as industry standard control and monitoring instruments. The main areas of application are low-pressure applications in hydraulics and pneumatics, particularly in refrigeration and air conditioning technology, the food and pharmaceutical industries. |
|||||||||
Type | N/A Electronic Pressure Transmitter | |||||||||
Model Code Description | N/A HDA 4345-A-0010-000-F1 | N/A HDA 4345-A-0016-000-F1 | N/A HDA 4345-A-01.0-000-E1 | N/A HDA 4345-A-02.5-000-F1 | N/A HDA 4345-B-0025-000-F1 | |||||
Input Overload Pressure | N/A 32 bar | N/A 50 bar | N/A 3 bar | N/A 8 bar | N/A 80 bar | |||||
Input Burst Pressure | N/A 48 bar | N/A 75 bar | N/A 5 bar | N/A 12 bar | N/A 120 bar | |||||
Mechanical Connection Type | N/A G1/4 A ISO 1179-2, Male | |||||||||
Mechanical Connection Size | N/A G 1/4 A, Male | |||||||||
Torque Value | N/A 20 N·m15 lb·ft | |||||||||
Output Signal | N/A 4 to 20 mA | N/A 4 to 20 mA | N/A 4 to 20 mA | N/A 4 to 20 mA | N/A 0 to 10 V | |||||
Output Permitted Load Resistance | N/A RLmax=(UB - 8 V)/20 mA (kΩ) | N/A RLmax=(UB - 8 V)/20 mA (kΩ) | N/A RLmax=(UB - 8 V)/20 mA (kΩ) | N/A RLmax=(UB - 8 V)/20 mA (kΩ) | N/A RLmin=2 (kΩ) | |||||
Output Typical Accuracy to DIN 16086 At Maximum Setting (Full Scale) | N/A ≤ ± 0.5 % | |||||||||
Output Maximum Accuracy to DIN 16086 At Maximum Setting (Full Scale) | N/A ≤ ± 1 % | |||||||||
Output Typical Accuracy at Minimum Setting Best Fit Straight Line (B.F.S.L) (Full Scale) | N/A ≤ ± 0.25 % | |||||||||
Output Maximum Accuracy at Minimum Setting Best Fit Straight Line (B.F.S.L) (Full Scale) | N/A ≤ ± 0.5 % | |||||||||
Output Typical Temperature Compensation Zero Point (Full Scale) | N/A ≤ ± 0.02 %/°C | |||||||||
Output Maximum Temperature Compensation Zero Point (Full Scale) | N/A ≤ ± 0.03 %/°C | |||||||||
Output Typical Temperature Compensation Over Range (Full Scale) | N/A ≤ ± 0.02 %/°C | |||||||||
Output Maximum Temperature Compensation Over Range (Full Scale) | N/A ≤ ± 0.03 %/°C | |||||||||
Output Maximum Non-Linearity at Maximum Setting to DIN 16086 (Full Scale) | N/A ≤ ± 0.5 % | |||||||||
Output Maximum Hysteresis (Full Scale) | N/A ≤ ± 0.4 % | |||||||||
Output Repeatability (Full Scale) | N/A ≤ ± 0.1 % | |||||||||
Output Rise Time | N/A ≤ 1 ms | |||||||||
Output Long-Term Drift Per Year (Full Scale) | N/A ≤ ± 0.3 % | |||||||||
Compensated Temperature Range | N/A -25 to 85 ºC | |||||||||
Storage Temperature Range | N/A -40 to 100 ºC | |||||||||
Fluid Temperature Range | N/A -25 to 100 ºC | |||||||||
Note for Fluid Temperature Range | N/A -20 ºC with FPM or EPDM seal, -40 ºC on request | |||||||||
Vibration Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz | N/A ≤ 20 g | |||||||||
Protection Class According to DIN EN 605293 | N/A IP 65 | |||||||||
Direct Current (DC) Supply Voltage When Applied According to UL Specifications | N/A 8 to 30 V | N/A 8 to 30 V | N/A 8 to 30 V | N/A 8 to 30 V | N/A 12 to 30 V | |||||
Residual Ripple of Supply Voltage | N/A ≤ 5 % | |||||||||
Electrical Connection | N/A Male, 3 Pole + PE, EN175301-803 (DIN 43650) (Connector Supplied) | |||||||||
Sensor Material | N/A Ceramic | |||||||||
No of Conductor | N/A 2 | N/A 2 | N/A 2 | N/A 2 | N/A 3 | |||||
Seal Material | N/A Fluorocarbon Elastomer (FKM) | |||||||||
Material of Connection | N/A Stainless Steel | |||||||||
Shock Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz Per 6 ms | N/A ≤ 100 g | |||||||||
Pin Connection 1 | N/A Signal+ | N/A Signal+ | N/A Signal+ | N/A Signal+ | N/A +UB | |||||
Pin Connection 2 | N/A Signal- | N/A Signal- | N/A Signal- | N/A Signal- | N/A 0 Voltage | |||||
Pin Connection 3 | N/A No Connection | N/A No Connection | N/A No Connection | N/A No Connection | N/A Signal | |||||
Pin Connection 4 | N/A | |||||||||
Pin Connection (Ground) | N/A Housing | |||||||||
Version | N/A | |||||||||
Current Consumption | N/A ≤ 25 mA | |||||||||
Operating Temperature Range | N/A -25 to 85 ºC176 ºF | N/A -25 to 85 ºC | N/A -25 to 85 ºC | N/A -25 to 85 ºC | N/A -25 to 85 ºC | |||||
Input Measuring Range | N/A 10 bar | N/A 16 bar | N/A 1 bar | N/A 2.5 bar | N/A 25 bar | |||||
BUn | N/A EA | |||||||||
Special Features |
N/A
|
|||||||||
Accessories | N/A Appropriate accessories, such as electrical female connectors, can be found in the Accessories brochure. | |||||||||
Note |
N/A
Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided. Subject to technical modifications. |
|||||||||
Core Products | N/A | |||||||||
Division | N/A ACCESSORIES | N/A | N/A ELECTRONICS | N/A ELECTRONICS | N/A | |||||
Product Group Family | N/A FLUID LEVEL GAUGES | N/A | N/A PRESSURE TRANSDUCERS | N/A PRESSURE TRANSDUCERS | N/A | |||||
Product | N/A ACCESSORIES / MISC | N/A | N/A PRESSURE TRANSDUCERS | N/A PRESSURE TRANSDUCERS | N/A | |||||
|