The robust and powerful TTC 2310 mid-sized electronic control solution is equipped with Infineon's TriCore™ Aurix™ TC 377 CPU to fulfill the demanding performance requirements of off-highway and automotive safety applications.

Protected by a compact and robust housing, the device was especially developed for vehicles and machines used in a rugged operating environment and at extreme operating temperatures. Due to the ISO 26262 ASIL C automotive safety certification, the device is also used inmore
Unit of Measure

Specifications

Model Code Description

TTC 2310-CP-10-FS5-000

Operating Temperature [Min]

-40 ºC

Operating Temperature [Max]

85 ºC

Software

C Programming Environment

Connector Type

Two 48 pin connectors

Operating Altitude

0 to 4000 m

Supply Voltage

8 to 32 V

Supply Current at 12/24 V without Load [Max]

130 mA200 mA

Standby Current

≤ 1 mA

Functional Safety

EN ISO 13849 PL d IEC 61508 SIL2 ISO 19014 MPL d ISO 25119 AgPL d SRL2 ISO 26262 ASIL C

European Conformity (CE) Mark

2006/42/EC 2014/30/EU

Electromagnetic Compatibility (EMC)

CISPR 25 EN 13766 IEC 61000-4-2/-3/-4/-5/-6/-8 IEC 61000-6-4 ISO 14982

Electrostatic Discharge (ESD)

ISO 10605

E - Mark

ECE-R10 Rev.6

Electrical

ISO 16750-2 ISO 7637-2,-3

Ingress Protection (IP) Class

EN 60529 IP65 and IP67 ISO 20653 IP6k9k

Climatic

ISO 16750-4

Mechanical

ISO 16750-3

ISOBUS

ISO 11783

Equipment Options

Developer Version

Weight

2.68 lb

Division

ELECTRONICS

Product Group Family

MOBILE CONTROLLERS

Product

MOBILE CONTROLLERS / IO MODULES

Dimensions

Length

170.6 mm

Depth

42 mm

Width

232 mm

Minimum Connector Release Clearance Height

50 mm

Minimum Connector Release Clearance Length

70 mm

Minimum Connector Release Clearance Width

182 mm

CPU Core

CPU Core

  • 32-Bit Infineon TriCore™ Aurix™ TC 377
  • 3 cores (2 lockstep cores) running at 300 MHz and memory protection for safety-relevant applications
  • Floating-Point Unit and Hardware Security Module
  • 992 KB int. SRAM, 6 MB int. Flash
  • 16 MB ext. Flash, 8 kB FRAM, 256 KB int. EEPROM emulation

Interface

Interface

  • 4 x CAN FD 50 kbit/s up to 2 Mbit/s (1 x CAN FD with wake-up capability and 1 x CAN FD ISOBUS)
  • 1 x CAN bus termination configurable via connector pins
  • 4 x SENT with SPC support, 1 x LIN

Output Type

Output Type

  • 10 x PWM OUT up to 1 kHz or digital OUT, up to 4 A (2 x up to 8 A), high side, with current measurement, alternative use as digital timer IN (0.1 Hz - 20 kHz) configurable pull-up in groups of 2 or analog IN 12 bit, 0 - 32 V or LED control OUT
  • 18 x digital OUT up to 4 A, high side, with current sense alternative use 4 x as voltage OUT 0 - 10 V or 10 x as PVG OUT, 10 - 90% of BAT+ or 8 x as digital timer IN (0.1 Hz - 20 kHz) or LED control OUT or analog IN 12 bit, 0 - 32 V
  • 8 x PWM OUT up to 4 kHz, up to 4 A, low side, with current measurement (4 x featuring timer feedback) alternative use as analog IN 12 bit, 0 - 5 V, 0 - 32 V or 4 x as digital timer IN (0.1 Hz - 20 kHz)
  • 1 x emergency stop OUT*, alternative use as analog IN 12 bit, 0 - 32 V
  • Option to configure up to 4 x H-bridges for motor control*
  • 3 x status LED

Input Type

Input Type

  • 8 x analog IN 12 bit, 0 - 5 V, 0 - 25 mA, 0 - 100 kOhm, LED control
  • 4 x analog IN 12 bit, 0 - 5 V, 0 - 32 V
  • 8 x digital timer IN (0.1 Hz - 20 kHz), encoder support, configurable pull-up/down, support for 7/14 mA current loop speed sensors alternative use as analog IN 12 bit, 0 - 32 V, 0 - 25 mA
  • 4 x digital timer IN (0.1 Hz - 20 kHz), encoder support, configurable pull-up, alternative use as analog IN 12 bit, 0 - 32 V or SENT interface
  • 2 x emergency stop IN*, alternative use as analog IN 12 bit, 0 - 32 V
  • Terminal 15 and Wake-Up pin

Other

Other

  • 2 x sensor supply, 5 V, max. 500 mA
  • 1 x sensor supply, 5 - 12 V, max. 2.5 W, configurable by SW in 0.5 V steps

Note

N/A All inputs and outputs supporting analog IN can also be used as digital Input. All I/Os and interfaces are protected against short circuit to GND and BAT+, and can be configured by software. Board temperature, sensor supply, and supply voltage are monitored by software. Two independent shut-off groups for output stages. For details on the standards, see the system manual.