Print Back
This version of the pressure transmitter series HDA 4700 has been specially developed for use in safety circuits/safety functions as part of the functional safety of machinery and equipment up to PL d - Cat 3 (in accordance with ISO 13849).

The pressure transmitters are designed with two channels. Each channel consists of a sensor element and evaluation electronics.

As a result, the pressure transmitter develops two separate and independent output signals in proportion to the pressure.

The safety function is tested by evaluating and comparing the two analogue output signals in a higher-level system.

The main fields of application are as sensor elements in mobile, safety-oriented systems such as load torque displays, load torque limitation in truck-mounted cranes or working platforms and much more.
HDA 4700 FuSi-frei.png
Unit of Measure
Items HDA 4700 FuSi-frei.png
922445
HDA 4700 Functional Safety Pressure Transducer
List Price QUOTE
HDA 4700 FuSi-frei.png
922522
HDA 4700 Functional Safety Pressure Transducer
List Price QUOTE
HDA 4700 FuSi-frei.png
922344
HDA 4700 Functional Safety Pressure Transducer
List Price QUOTE
HDA 4700 FuSi-frei.png
926626
HDA 4700 Functional Safety Pressure Transducer
List Price QUOTE
HDA 4700 FuSi-frei.png
928273
HDA 4700 Functional Safety Pressure Transducer
List Price QUOTE
Description N/A This version of the pressure transmitter series HDA 4700 has been specially developed for use in safety circuits/safety functions as part of the functional safety of machinery and equipment up to PL d - Cat 3 (in accordance with ISO 13849).

The pressure transmitters are designed with two channels. Each channel consists of a sensor element and evaluation electronics.

As a result, the pressure transmitter develops two separate and independent output signals in proportion to the pressure.

The safety function is tested by evaluating and comparing the two analogue output signals in a higher-level system.

The main fields of application are as sensor elements in mobile, safety-oriented systems such as load torque displays, load torque limitation in truck-mounted cranes or working platforms and much more.
Model Code Description N/A HDA 4746-CC-0400-0400-Pd-000 N/A HDA 4746-CC-0250-0250-Pd-000 N/A HDA 4746-CC-0100-0100-Pd-000 N/A HDA 474V-CC-0250-0250-Pd-000 N/A HDA 476V-CC-5000-5000-Pd-000(psi)
Mechanical Connection Type N/A G1/4 A ISO 1179-2, Male with 0.5 mm orifice N/A G1/4 A ISO 1179-2, Male with 0.5 mm orifice N/A G1/4 A ISO 1179-2, Male with 0.5 mm orifice N/A G1/4 A ISO 1179-2, Male with 0.5 mm orifice N/A SAE-4, male (7/16-20 UNF 2A)
Measuring Range for Signal 1 and 2 N/A 0 to 400 bar N/A 0 to 250 bar N/A 0 to 100 bar N/A 0 to 250 bar N/A 0 to 5000 psi
Input Overload Pressure N/A 800 bar N/A 500 bar N/A 200 bar N/A 500 bar N/A 11600 psi
Input Burst Pressure N/A 2000 bar N/A 1250 bar N/A 500 bar N/A 1250 bar N/A 29000 psi
Mechanical Connection Size N/A G1/4 N/A G1/4 N/A G1/4 N/A G1/4 N/A SAE-4
Output Signal N/A 4-20 mA for signal 1 and signal 2. 3 conductor
Wetted Material N/A Stainless Steel and FKM Seal
Electrical Connection N/A Male 4 Pole M12 N/A Male 4 Pole M12 N/A Male 4 Pole M12 N/A Male 4 Pole Deutsch DT04-4P N/A Male 4 Pole Deutsch DT04-4P
Power Supply N/A 7 to 35 V DC (max. load resistance 250 ohms)

12 to 35 V DC (max. load resistance 500 ohms)
Output Typical Accuracy According to DIN 16086, Terminal Based (Full Scale) N/A ≤ ± 0.25 %
Output Typical Accuracy Best Fit Straight Line (B.F.S.L) (Full Scale) N/A ≤ ± 0.15 %
Output Maximum Accuracy Best Fit Straight Line (B.F.S.L) (Full Scale) N/A ≤ ± 0.25 %
Output Maximum Temperature Compensation Zero Point (Full Scale) N/A ≤ ± 0.015 %/°C
Output Typical Temperature Compensation Over Range (Full Scale) N/A ≤ ± 0.008 %/°C
Output Maximum Temperature Compensation Over Range (Full Scale) N/A ≤ ± 0.015 %/°C
Output Maximum Non-Linearity According to DIN 16086 Terminal Based (Full Scale) N/A ≤ ± 0.3 %
Output Maximum Hysteresis (Full Scale) N/A ≤ ± 0.1 %
Output Repeatability (Full Scale) N/A ≤ ± 0.05 %
Output Rise Time N/A ≤ 2 ms
Output Long-Term Drift Per Year (Full Scale) N/A ≤ ± 0.1 %
Vibration Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz N/A ≤ 20 g
Shock Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz Per 6 ms N/A ≤ 100 g
Pin Connection 1 N/A +UB
Pin Connection 2 N/A Signal 2 N/A Signal 2 N/A Signal 2 N/A 0 Voltage N/A 0 Voltage
Pin Connection 3 N/A 0 Voltage N/A 0 Voltage N/A 0 Voltage N/A Signal 2 N/A Signal 2
Pin Connection 4 N/A Signal 1
Current Consumption N/A ≤ 50 mA
Approvals N/A > 10 Million Cycles
Residual Ripple of Supply Voltage N/A > 10 Million Cycles %
Operating Temperature [Min] N/A -25 ºC N/A -25 ºC N/A -25 ºC N/A -25 ºC N/A -13 ºF
Operating Temperature Range N/A 85 ºC N/A 85 ºC N/A 85 ºC N/A 85 ºC N/A 185 ºF
Compensated Temperature Range N/A -25 to 85 ºC N/A -25 to 85 ºC N/A -25 to 85 ºC N/A -25 to 85 ºC N/A -25 to 185 ºF
Storage Temperature Range N/A -40 to 85 ºC N/A -40 to 85 ºC N/A -40 to 85 ºC N/A -40 to 85 ºC N/A -40 to 185 ºF
Protection Class According to DIN EN 605293 N/A IP 69
Torque Value N/A 20 N·m
Industry Standards/Certifications N/A CE Mark EN 61000-6-1/2/3/4
Weight N/A 0.397 lb
Operating Pressure Signal 1 N/A N/A N/A N/A N/A 0 to 5000 psi
Operating Pressure Signal 2 N/A N/A N/A N/A N/A 0 to 5000 psi
Special Features N/A Safety-related data

Performance level based on DIN EN ISO 13849-1: 20008

Protection level: d

Architecture: Category 3
Note N/A Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.
Subject to technical modifications.
Core Products N/A
Division N/A ELECTRONICS
Product Group Family N/A PRESSURE TRANSDUCERS
Product N/A PRESSURE TRANSDUCERS