Print Back
The pressure transmitter HDA 4700-H with HSI sensor recognition was specially developed for use in conjunction with the HYDAC measuring instruments HMG 5X0, HMG 2500, HMG 4000 and CMU 1000. For data transmission, the HDA 4700-H has an HSI interface (HYDAC Sensor Interface).

The HSI sensors are automatically recognized via the HSI interface by the above-mentioned HYDAC measuring instruments and all necessary basic device settings are taken from each sensor.

Like all pressure transmitters of the HDA 4700 series, the HDA 4700-H also has a very accurate and robust sensor cell with a thin-film strain gauge on a stainless steel membrane. It combines excellent technical data with a very compact design.
HE_HDA 4748-H_sw.png
Unit of Measure
Items HE_HDA 4748-H_sw.png
909425
HDA 4700 HSI Pressure Transducer
List Price QUOTE
HE_HDA 4748-H_sw.png
909554
HDA 4700 HSI Pressure Transducer
List Price QUOTE
HE_HDA 4748-H_sw.png
909426
HDA 4700 HSI Pressure Transducer
List Price QUOTE
HE_HDA 4748-H_sw.png
909337
HDA 4700 HSI Pressure Transducer
List Price QUOTE
HE_HDA 4748-H_sw.png
909427
HDA 4700 HSI Pressure Transducer
List Price QUOTE
Description N/A The pressure transmitter HDA 4700-H with HSI sensor recognition was specially developed for use in conjunction with the HYDAC measuring instruments HMG 5X0, HMG 2500, HMG 4000 and CMU 1000.

For data transmission, the HDA 4700-H has an HSI interface (HYDAC Sensor Interface).

The HSI sensors are automatically recognized via the HSI interface by the above-mentioned HYDAC measuring instruments and all necessary basic device settings are taken from each sensor.

Like all pressure transmitters of the HDA 4700 series, the HDA 4700-H also has a very accurate and robust sensor cell with a thin-film strain gauge on a stainless steel membrane. It combines excellent technical data with a very compact design.
Type N/A Electronic Pressure Transmitter
Model Code Description N/A HDA 4748-H-0016-000 N/A HDA 4748-H-0060-000 N/A HDA 4748-H-0100-000 N/A HDA 4748-H-0250-000 N/A HDA 4748-H-0400-000
Mechanical Connection Type N/A G1/4 A ISO 1179-2, Male
Weight N/A
Input Burst Pressure N/A 200 bar N/A 300 bar N/A 500 bar N/A 1000 bar N/A 2000 bar
Mechanical Connection Size N/A G 1/4 A, Male
Output Signal N/A HSI (HYDAC Sensor Interface) Automatic Sensor Recognition
Wetted Material N/A
Electrical Connection N/A Male M12 x 1, 5 Pole (Connector Not Supplied)
Power Supply N/A
BUn N/A EA
No of Conductor N/A 5
Output Typical Accuracy According to DIN 16086, Terminal Based (Full Scale) N/A ≤ ± 0.25 %
Output Typical Accuracy Best Fit Straight Line (B.F.S.L) (Full Scale) N/A ≤ ± 0.15 %
Output Maximum Accuracy Best Fit Straight Line (B.F.S.L) (Full Scale) N/A ≤ ± 0.25 %
Output Typical Temperature Compensation Zero Point (Full Scale) N/A ≤ ± 0.008 %/°C
Output Maximum Temperature Compensation Zero Point (Full Scale) N/A ≤ ± 0.015 %/°C
Output Typical Temperature Compensation Over Range (Full Scale) N/A
Output Maximum Temperature Compensation Over Range (Full Scale) N/A
Output Typical Temperature Compensation Span (Full Scale) N/A ≤ ± 0.008 %/°C
Output Maximum Temperature Compensation Span (Full Scale) N/A ≤ ± 0.015 %/°C
Output Maximum Non-Linearity at Maximum Setting to DIN 16086 (Full Scale) N/A ≤ ± 0.3 %
Output Maximum Non-Linearity According to DIN 16086 Terminal Based (Full Scale) N/A
Seal Material N/A Fluorocarbon Elastomer (FKM)
Material of Connection N/A Stainless Steel
Output Maximum Hysteresis (Full Scale) N/A ≤ ± 0.1 %
Output Repeatability (Full Scale) N/A ≤ ± 0.05 %
Output Rise Time N/A ≤ ± 1 ms
Output Long-Term Drift Per Year (Full Scale) N/A ≤ ± 0.1 %
Note for Direct Current (DC) Supply Voltage When Applied According to UL Specifications N/A via HYDAC measuring instruments HMG 500, HMG 510, HMG 3000, HMG 3010 or CMU 1000
Vibration Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz N/A ≤ 20 g
Life Expectancy (0 to 100% Full Scale (FS)) N/A > 10 Million Cycles
Input Overload Pressure N/A 32 bar N/A 120 bar N/A 200 bar N/A 500 bar N/A 800 bar
Input Measuring Pressure Range N/A 0 to 16 bar N/A 0 to 60 bar N/A 0 to 100 bar N/A 0 to 250 bar N/A 0 to 400 bar
Operating Temperature [Min] N/A
Operating Temperature Range N/A -25 to 85 ºC-13 to 185 ºF
Compensated Temperature Range N/A -25 to 85 ºC
Storage Temperature Range N/A -40 to 100 ºC
Fluid Temperature Range N/A -25 to 100 ºC
Note for Fluid Temperature Range N/A -25 ºC (-13 ºF) with FKM seal, -40 ºC (-40 ºC) on request
Operating Pressure [Min] N/A 0 bar
Operating Pressure [Max] N/A 16 bar N/A 60 bar N/A 100 bar N/A 250 bar N/A 400 bar
Protection Class According to DIN EN 605293 N/A IP 67
Torque Value N/A 20 N·m15 lb·ft
Industry Standards/Certifications N/A CE Mark EN 61000-6-1/2/3/4
Accessories N/A Appropriate accessories, such as electrical female connectors, can be found in the Accessories brochure.
Special Features N/A
  • Fully automatic recognition by, and voltage supply from, HYDAC measuring instruments HMG 500, HMG 510, HMG 3000, HMG 3010 or CMU 1000
  • Automatic transfer of measuring range, measured value and measurement unit
  • Highly Robust Sensor Cell
  • Very Small Temperature Error
  • Excellent EMC Characteristics
  • Excellent Long Term Stability
  • Very Compact Design
Note N/A Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.
Subject to technical modifications.
Core Products N/A
Division N/A ELECTRONICS
Product Group Family N/A PRESSURE TRANSDUCERS
Product N/A PRESSURE TRANSDUCERS