Print Back
The CS1000 series of contamination monitoring sensor offers Continuous measurement of particulate contamination. Online, real-time condition monitoring allows for total predictive maintenance.
Unit of Measure

Specifications

Type

Contamination Sensor

Model Code Description

CS 1220-B-0-0-0-0/-000

Weight

1.3 kg2.9 lb

Series

CS

Resolution

4 Particle Size Channels

Indicator Code

ISO 4406 : 1999; SAE AS 4059 (D)
4 μm(c) >6 μm(c) >14 μm(c) >21 μm(c)

Options

With Display (270º Rotation of Display)

Electrical Connection

Plug M12x1, 8-Pole (Connection cable not included)

Mounting

Inline Version

Modification

Standard

BUn

EA

Division

FILTER SYSTEMS

Product Group Family

CONTAMINATION SENSORS

Product

CONTAMINATION SENSORS/CTU

Technical Specifications

Self-Diagnosis

Continuously with error indication via status LED

Measuring Range - Display up to Class

ISO 7/6/5 to 28/27/26

Measuring Range - Calibration within the Range

ISO 13/11/10 to 23/21/18

Contamination Code

ISO 4406 : 1999, SAE AS 4059 (D)

Operation Pressure [Max] (Sensor Only)

350 bar5075 psi

Operation Pressure (Through Manifold Block)

3500 psi

Inlet Connector Size

G 1/4

Inlet Connector Type

ISO 228

Outlet Connector Size

G 1/4

Outlet Connector Type

ISO 228

Sensor Flow Rate

1.8 to 30 in³/min30 to 500 mL/min

Permissible Viscosity Range

1 to 1000 cSt15 to 4635 SUS

Fluid Temperature Range

0 to 85 ºC32 to 185 ºF

Power Supply Voltage

9 to 36 VDC

Residual Ripple of Supply Voltage

≤ 10 %

Power Consumption [Max]

3 W

Minimum Resistance

820 O

Maximum Current

1.5 A

Analog Interfaces

2 to 10 V

Limit Switching Output

Passive, n-Switching Power MOSFET

Digital Interfaces

RS485 - 2 Conductor Cable

Ambient Temperature Range

-30 to 80 ºC-22 to 176 ºF

Relative Humidity [Max] - Non-Condensing

95 %

Seal Material

Fluoroelastomer (FPM)

Fluids

Hydraulic/Mineral Oil

Electrical Safety Class

III (Low Voltage Protection)

IP Class

IP 67

Mounting Position

Recommended vertical with direction of flow south to north

Scope of Delivery

N/A

  • Contamination sensor
  • Calibration Certificate
  • Operation and Instruction manual
  • CD with FluMoS Light software and manuals

Application

N/A Monitoring system on vehicles such as

  • Construction equipment
  • Agricultural machinery
  • Mobile and stationary equipment
Industrial hydraulic systems
  • Integration into power unit monitoring systems
  • Hydraulic test stands
Combination with filter unit

Features

N/A

  • Version with or without display
  • Display with pivot-function
  • Display with 6-digit ISO Code (optional)
  • Measurement of solid particle contamination in hydraulic and lubricating fluids
  • Compact and rugged design
  • Data output 4 - 20 mA or 2 to 10 V (min 820 Ω)

Accessories

N/A

  • Connection cable 6.5 ft. with M12x1 connector, screened 8-pole: Part Number 03281220
  • Connection cable 16.4 ft. with M12x1 connector, screened 8-pole: Part Number 02702459
  • Connection cable 9.8 ft. with M12x1 connector, 8-pole: Part Number 02091414
  • CSI-D-5 Contamination Sensor Interface: Part Number 03249563
  • Power Supply-CS1XXX-PS1: Part Number 03376530

Note

N/A We do not guarantee the accuracy or completeness of this information. The information is based on average working condition. For exceptional operating conditions please contact our technical department. All details are subject to technical changes.