Print Back
The sensor works on the principle of magnetostriction.

This measuring principle determines with high accuracy the position, distance and/or speed and is based on elapsed time measurement.

Utilizing this non-contact and wear-free measuring system, HYDAC offers a version in a pressure-resistant, tubular casing in stainless steel, for direct installation into hydraulic cylinders.
Unit of Measure

Specifications

Model Code Description

N/A HLT 2100-R1-K01-C01-0752-000

Type

N/A Externally Mounted Linear Transducer

Weight

N/A 2.88 lb

Mounting Type

N/A Externally Mounted Linear Transducer with M18 x 1.5 Screw-In Flange

Operating Temperature [Min]

N/A 0 ºC

Operating Temperature [Max]

N/A 70 ºC

Measuring Range

N/A 0 to 752 mm

Output Type

N/A 4 to 20 mA

Sensor Type

N/A Magnetostrictive

Output Maximum Hysteresis (Full Scale)

N/A 0.02 mm (Measuring range less than or equal to 1500 mm)

0.1 mm (Measuring range greater than 1500 mm)

Output Repeatability (Full Scale)

N/A ≤ 0.005 to ≤ 0.05 mm (Depends on Length)

Resolution

N/A 16 Bit; min. 0.005 mm

Non-Linearity

N/A ±0.1 mm (Measuring Range ≤ 1500 mm)

±0.15 mm (Measuring Range > 1500 mm)

Temperature Coefficient

N/A ≤ ± 0.004% Full Scale (FS)/ ºC

Sampling Rate

N/A Depending on Length:

≤ 1 m: 0.5 ms

≤ 2 m: 1.0 ms

≤4 m: 2.0 ms

Industry Standards/Certifications

N/A European Conformity (CE) Mark European Standard (EN) 61000-6-1/2/3/4

Vibration Resistance According to DIN EN 60068-2-6

N/A ≤ 10 g at 50 to 2000 Hz

Shock Resistance According to DIN EN 60068-2-27 (11 ms)

N/A ≤ 100 g

Operating Pressure

N/A ≤ 6525 psi

Peak Pressure According to DIN EN ISO 19879

N/A 10876 psi

Sensor Material

N/A Rod: Stainless Steel 1.4571

Housing: Aluminum

Electrical Connection

N/A Jacketed Cable, Length 1 Meter

Power Supply

N/A 24 V DC ± 10%

Current Consumption

N/A ≤ 100 mA

Residual Ripple of Supply Voltage

N/A ≤ 250 mVpp

Brown Wire Core

N/A 0V (Analog Output)

Green Wire Core

N/A Start Point

Yellow Wire Core

N/A End Point

Blue Wire Core

N/A +Ub

Pink Wire Core

N/A 0V

Grey Wire Core

N/A Signal

Storage Temperature Range

N/A -30 to 85 ºC

Degree of Protection

N/A IP 65

Installation Position

N/A No Restriction

Torque Value

N/A 50 N·m

Division

N/A ELECTRONICS

Product Group Family

N/A POSITION SENSORS

Product

N/A POSITION SENSOR

Note

N/A Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.

Additional Information

N/A The different output signals (analogue current / voltage) enable connection to all HYDAC ELECTRONIC GmbH measurement and control devices as well as connection to standard evaluation systems (e.g. to PLC controls).

External set inputs for the analogue start point and end point offer an additional possibility of a customised adjustment.

HLT 2100 is primarily used in stationary applications as partially integrated solutions in hydraulic cylinders.