Maximum Operating Pressure per Port (P1, A, B) |
N/A 4,350 psi300 bar |
Maximum Operating Pressure per Port (T1, T2, T3, T4) |
N/A 300 psi20 bar |
Typical Nominal Inlet Flow Rate |
N/A 30 gpm110 L/min |
Fluid Temperature |
N/A 5 to 176 ºF-15 to 80 ºC |
Spool Control Force at Neutral Position |
N/A 25 lb110 N |
Spool Control Force at Maximum Spool Stroke |
N/A 29 lb130 N |
Permissible Contamination Level |
N/A Equal or Better than 20/18/14 as per ISO 4406 |
Viscosity1 | N/A 10 to 400 mm²/s |
Leakage2 | N/A ≤ 13 cm³/min |
Pressure Fluid |
N/A Mineral Oil and Synthetic Oil Based on Mineral Oil HL, HLP according to DIN 51524 |
Q-Function |
N/A The flow control (Q-function) of the inlet section by-passes the major part of the pump flow to tank when the system is idling, still giving access to full pump flow when the services are operated. Besides greatly reducing heat generation this also provides improved operating characteristics. |
Remote Control |
N/A The RS 220 is designed with an integrated pilot supply system in order to achieve an easy installation and a reliable remote control function. It is also possible (and in some cases preferred) to supply the pilot system externally. |
Properties and Possibilities |
N/A
|
N/A
The electro-hydraulic proportional version in particular offers compact design with internal pilot oil supply, solenoids integrated in the valve body and integral hand levers for manual override/manual operation. |