The programmable pressure switch EDS 4400 in ATEX version has been specially developed for use in potentially explosive atmospheres, and is based on the EDS 4000 series.

The switching point and switchback point, the function of the switching outputs as N/C or N/O and the switching delay are userprogrammable in conjunction with the HYDAC Programming Unit HPG 3000.

As with the industry model, the programmable EDS 4400 in ATEX version has a stainless steel measurement cell with thin-film strainmore
Unit of Measure

Specifications

Industry Standards/Certifications

CE Mark EN 61000-6-1/2/3/4

EN 60079-0/11/26

EN 61241-0/11

EN 50303

Model Code Description

EDS 4448-0060-P-AN1-000

Mechanical Connection Type

G1/4 A DIN 3852, Male

Weight

0.331 lb

Approvals

DEKRA EXAM BVS 07 ATEX E 041 X
This pressure switch is for protection type I M1 Ex ia I

Burst Pressure

300 bar

Connection Size

G1/4

Switch Type

1 PNP Transistor Output

Response Time

8 ms

Switching Function

Adjustable N/O or N/C

Electrical Connection

Male M12, 5 Pole

Power Supply

14 to 28 V DC

Accuracy

1% FS Max

Pin Connection 1

+UB

Pin Connection 2

0V

Pin Connection 3

0V

Pin Connection 4

Out 1

Pin Connection 5

0V

Recommended Tightening Torque

20 N·m

Output Typical Temperature Compensation Zero Point (Full Scale)

≤ ± 0.03 %/°C

Output Maximum Temperature Compensation Zero Point (Full Scale)

≤ ± 0.03 %/°C

Output Typical Temperature Compensation Span (Full Scale)

≤ ± 0.03 %/°C

Output Maximum Temperature Compensation Span (Full Scale)

≤ ± 0.03 %/°C

Maximum Output Repeatability (Full Scale)

≤ ± 0.1 %

Switching Cycles

> 100 Million

Vibration Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz

≤ 20 g

Maximum Total Current Consumption

0.1 A

Residual Ripple of Supply Voltage

≤ 5 %

Output Long-Term Drift Per Year (Full Scale)

≤ ± 0.3 %

Increment (Switch Point)

0.1 bar

Setting Options

In conjunction with the HYDAC Programming Unit HPG 3000, all the setting are combined in an easy to follow menu.

Overload Pressure

120 bar

Switching Current

0.034 A

Operating Pressure [Max]

60 bar

Degree of Protection

IP 67

Storage Temperature Range

-40 to 100 ºC

Fluid Temperature Range

-40 to 60 ºC

Switching Power Rating

0.7 W

T6 Compensated Temperature Range

-20 to 60 ºC

T5, T4 Compensated Temperature Range

-20 to 70 ºC

T100 Compensated Temperature Range

-20 to 70 ºC

Division

ELECTRONICS

Product Group Family

PRESSURE SWITCHES

Product

PRESSURE SWITCHES

Note

N/A Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.