Unit of Measure

Specifications

Type

N/A In-Line High Pressure Filter

Model Code Description

N/A MFM ON 35OI20A4.0/B7

Size

N/A 35

Weight

N/A 8.2 lb

Type Number

N/A Indicator Port on Top of Head - 4 Mounting Holes (Standard)

Modification Number

N/A Latest Version Always Supplied

Indication Type

N/A A = No indicator, plugged port

BUn

N/A EA

Division

N/A HYDRAULIC AND LUBE FILTERS

Product Group Family

N/A FILTERS-HIGH PRESSURE (ò3000 PSI)

Product

N/A FILTERS-HIGH PRESSURE (>3000PSI)

Technical Specifications

Flow Capacity

N/A 10 gpm35 L/min

Maximum Allowable Housing Working Pressure Rating

N/A 280 bar4000 psi

Filter Rating

N/A 20 µm

Construction Material for Head

N/A Ductile Iron

Construction Material for Bowl

N/A Steel

Mounting Method

N/A 4 Mounting Holes - Filter Head

Minimum Fluid Temperature

N/A -10 ºC14 ºF

Maximum Fluid Temperature

N/A 100 ºC212 ºF

Note for Fluid Temperature Range

N/A Consult HYDAC for applications operating below 14ºF (-10ºC)

Bypass Valve Cracking Pressure

N/A 7 bar100 psid

Tolerance for Cracking Pressure (Standard)

N/A 10 %

Tolerance for Cracking Pressure (Optional)

N/A 10 %

Fatigue Housing Pressure Rating at 1 Million Cycles

N/A 280 bar4060 psi

Element Collapse Pressure Rating

N/A 20 bar290 psi

Burst Housing Pressure Rating

N/A 960 bar13920 psi

Fluid Compatibility

N/A Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected.

Dimensions

Dimension b1

N/A 3.62 in92 mm

Diameter d1

N/A 3.39 in86 mm

Dimension h1

N/A 6.3 in160 mm

Features

N/A

  • Because of their efficient design and construction, MFM filters are considered a cost effective solution for new equipment, or as a replacement for filters already specified on existing equipment.
  • The MFM filter is available in 4 sizes comprised of four different bowl and element lengths. The models 35, 55, 75, and 95, provide maximum flow rates of 10, 18, 20, and 25GPM respectively.
  • A quick-response bypass valve located in filter head protects against high differential pressures caused by cold startups, flow surges and pressure spikes.
  • The high bypass pressure setting (100 psid) minimizes the possibility of contamination due to premature bypassing.
  • Filter materials are compatible with all mineral, lubricating oils, and commonly used fire retardant fluids per ISO 2943.
  • Fatigue pressure rating equals maximum allowable working pressure rating.

Application

N/A

  • Agricultural
  • Automotive
  • Construction
  • Gearboxes
  • Industrial
  • Commercial Municipal