A versatile, base ported high flow particulate filter housing for use with diesel fuel. The QF5 can be configured in a single housing assembly to support 300 gpm of flow, or expand the capacity by choosing the 2QF5 assembly configured in parallel.
Unit of Measure

Specifications

Series

QF5

Element Length

39 in

Element Style

Q

Micron Rating

03 - 3 µm ECOmicron® 05 - 5 µm ECOmicron® 10 - 10 µm ECOmicron®

Housing Seal Material

(Omit) - Buna N V - Fluorocarbon Elastomer (FKM)

Porting

F32 - (-32 (2 in.) SAE 4-Bolt Flange Code 61) F40 - (-40 (2 1/2 in.) SAE 4-Bolt Flange Code 61) F48 - (-48 (3 in.) SAE 4-Bolt Flange Code 61) P32 - 2 in. NPTF P40 - 2 1/2 in. NPTF P48 - 3 in. NPTF S32 - SAE -32 O-Ring Boss

Differential Pressure Clogging Indicator Options

(Omit) - None VM - Visual pop-up, manual reset

Compatible Fluid Types

Biodiesel (with FKM Seals) Diesel Fuel

Dirt Holding Capacity

Dirt Holding Capacity at 3 µm Micron Rating

1293 g

Dirt Holding Capacity at 5 µm Micron Rating

1302 g

Dirt Holding Capacity at 10 µm Micron Rating

1214 g

Technical Specifications

Flow Rating1 Up to 300 gpmUp to 1135 L/min

Maximum Operating Pressure

500 psi35 bar

Minimum Yield Pressure Per National Fire Protection Association (NFPA) T2.6.1-R1-2005

2500 psi172 bar

Rated Fatigue Pressure

Contact Factory

Temperature Range

-20 to 212 ºF-29 to 100 ºC

Bypass Setting Cracking Pressure

30 psi2.1 bar

Bypass Setting Full Flow Pressure

55 psi3.8 bar

Porting Head Element Case

Cast Aluminum Steel

Cap

Ductile Iron

Weight of QF539

185 lb84 kg

Element Change Clearance for 39Q

33.8 in858 mm

Applications

Applications

  • Industrial
  • Automotive manufacturing
  • Machine tool
  • Steel making
  • Mining technology
  • Power generation
  • Pulp & paper
  • Bulk fuel filtration

Features

N/A

  • Element changeout from the top minimizes fuel spillage
  • For fuel filtration applications, the ECOmicron® is chosen as standard with FKM seals.
  • Offered in pipe, SAE straight thread, and flange porting
  • Optional inlet and outlet test points
  • Various element service indicator options

Note

N/A For applications requiring higher flow rates of 300 to 600 gpm, or increased contamination holding capacity for flow rates of up to 300 gpm, please contact the factory regarding the 2QF5 solution.

Model No. of filter in photograph is QF539QZ10P32.

For electrical indicators, contact factory.

  • 1 For 150 SUS (32 cSt) fluids