The pressure transmitter series HDA 4100 has a ceramic pressure measurement cell with thick-layer strain gauge which has been specially developed for measuring absolute pressure in the low-pressure range. The output signals 4 .. 20 mA or 0 .. 10 V allow connection of all HYDAC ELECTRONIC GMBH measurement and control devices as well as industry standard open- and closed-loop control instruments. The main fields of application are low pressure applications in hydraulics and pneumatics,more
Unit of Measure

Specifications

Model Code Description

HDA 4145-A-02.5-000-F1

Industry Standards/Certifications

CE Mark: EN 61000-6-1 / 2 / 3 / 4

Type

Absolute Pressure Transducer

Mechanical Connection Type

G1/4 A ISO 1179-2, Male

Weight

0.33 lb

Housing Material

Stainless Steel

Burst Pressure

12 bar

Output Signal

4 to 20 mA

Wetted Material

Mechanical Connection: Stainless Steel

Sensor Cell: Ceramic

Seal: FKM

Electrical Connection

Male, EN175301-803, 3 Pole + PE

DC Power Supply Voltage

8 to 30 V

Output Typical Accuracy According to DIN 16086, Terminal Based (Full Scale)

≤ ± 0.5 %

Output Maximum Accuracy According to DIN 16086, Terminal Based (Full Scale)

≤ ± 1

Output Typical Accuracy Best Fit Straight Line (B.F.S.L) (Full Scale)

≤ ± 0.25 %

Output Maximum Accuracy Best Fit Straight Line (B.F.S.L) (Full Scale)

≤ ± 0.5 %

Output Typical Temperature Compensation Zero Point (Full Scale)

≤ ± 0.02 %/°C

Output Maximum Temperature Compensation Zero Point (Full Scale)

≤ ± 0.03 %/°C

Output Typical Temperature Compensation Span (Full Scale)

≤ ± 0.02 %/°C

Output Maximum Temperature Compensation Span (Full Scale)

≤ ± 0.03 %/°C

Output Maximum Non-Linearity at Maximum Setting to DIN 16086 (Full Scale)

≤ ± 0.5 %

Output Maximum Hysteresis (Full Scale)

≤ ± 0.4 %

Output Repeatability (Full Scale)

≤ ± 0.1 %

Output Rise Time

≤ 1 ms

Output Long-Term Drift Per Year (Full Scale)

≤ ± 0.3 %

CUL®US Mark

Certificate Number: E318391

Vibration Resistance According to DIN EN 60068-2-6 at 10 to 500 Hz

≤ 20 g

Shock Resistance According to DIN EN 60068-2-27 (11 ms)

≤ 100 g / 6 ms

Pin Connection 1

Signal +

Pin Connection 2

Signal -

Pin Connection 3

Not Connected

Pin Connection (Ground)

Housing

Current Consumption

≤ 25 mA

Residual Ripple of Supply Voltage

≤ 5 %

Life Expectancy (0 to 100% Full Scale (FS))

> 10 Million Cycles

Overload Pressure

8 bar

Operating Temperature [Min]

-25 ºC

Operating Temperature [Max]

85 ºC

Compensated Temperature Range

-25 to 85 ºC

Storage Temperature Range

-40 to 100 ºC

Fluid Temperature Range

-25 to 100 ºC

Operating Pressure [Min]

0 bar

Operating Pressure [Max]

2.5 bar

Degree of Protection

IP 67

Torque Value

20 N·m

Note

N/A Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.