Print Back
The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and is based on elapsed time measurement.

Utilizing this non-contact and wear-free measuring system, HYDAC offers a flat profile housing version in aluminium. The different output signals (analogue current / voltage) enable connection to all HYDAC ELECTRONIC GmbH measurement and control devices as well as standard evaluation systems (e.g. PLC controls) External set inputs for the analogue start point and end point offer an additional possibility of a customised adjustment.

The HLT 2500-F1 is primarily used in stationary applications, especially when a partially integrated solution in hydraulic cylinders is not possible.
Elect_PositSens_Linear_HLT2500F1.jpg
Unit of Measure
Items Elect_PositSens_Linear_HLT2500F1.jpg
923016
HLT 2500-F1 Flat Profile Linear Transducer
List Price QUOTE
Elect_PositSens_Linear_HLT2500F1.jpg
923762
HLT 2500-F1 Flat Profile Linear Transducer
List Price QUOTE
Elect_PositSens_Linear_HLT2500F1.jpg
925673
HLT 2500-F1 Flat Profile Linear Transducer
List Price QUOTE
Description N/A The sensor works on the principle of magnetostriction.

This measuring principle determines with high accuracy the position, distance and/or speed and is based on elapsed time measurement.

Utilising this non-contact and wear-free measuring system, HYDAC offers a flat profile housing version in aluminum.
Model Code Description N/A HLT 2500-F1-K01-B01-0800-000 N/A HLT 2500-F1-M08-C01-1300-000 N/A HLT 2500-F1-K01-B02-1100-000
Weight N/A 2.88 lb
Mounting Type N/A Flat Profile Linear Transducer
Operating Temperature [Min] N/A 0 ºC
Operating Temperature [Max] N/A 70 ºC
Measuring Range N/A 0 to 800 mm N/A 0 to 1300 mm N/A 0 to 1100 mm
Output Type N/A 0 to 10 V N/A 4 to 20 mA N/A 10 to 0 V
Sensor Type N/A Magnetostrictive
Output Maximum Hysteresis (Full Scale) N/A 0.1 mm
Output Repeatability (Full Scale) N/A ≤ 0.05 - ≥ 0.5 mm (Depends on Length)
Resolution N/A 12 Bit, ≥ 0.05 mm
Non-Linearity N/A ±0.15 mm (Measuring Range ≤ 1500 mm)

±0.2 mm (Measuring Range > 1500 mm)
Temperature Coefficient N/A ≤ ± 0.004% Full Scale (FS)/ ºC
Sampling Rate N/A Depending on Length:

≤ 1 m: 1.0 ms

≤ 2 m: 2.0 ms

≤ 3 m: 3.0 ms

> 3 m: 3.5 ms
Industry Standards/Certifications N/A European Conformity (CE) Mark European Standard (EN) 61000-6-1/2/3/4
Vibration Resistance According to DIN EN 60068-2-6 N/A ≤ 10 g at 50 to 2000 Hz
Shock Resistance According to DIN EN 60068-2-27 (11 ms) N/A ≤ 100 g
Sensor Material N/A Housing: Aluminum
Electrical Connection N/A Jacketed Cable, Length 1 Meter N/A Male M16, 8 Pole N/A Jacketed Cable, Length 1 Meter
Pin Connection 1 N/A N/A Not Connected N/A
Pin Connection 2 N/A N/A 0V (Analogue Output) N/A
Pin Connection 3 N/A N/A Start Point N/A
Pin Connection 4 N/A N/A End Point N/A
Pin Connection 5 N/A N/A Signal N/A
Pin Connection 6 N/A N/A 0V N/A
Pin Connection 7 N/A N/A +Ub N/A
Pin Connection 8 N/A N/A Not Used N/A
Power Supply N/A 24 V DC ± 10%
Current Consumption N/A ≤ 100 mA
Residual Ripple of Supply Voltage N/A ≤ 250 mVpp
Brown Wire Core N/A 0V (Analog Output) N/A N/A 0V (Analog Output)
Green Wire Core N/A Start Point N/A N/A Start Point
Yellow Wire Core N/A End Point N/A N/A End Point
Blue Wire Core N/A +Ub N/A N/A +Ub
Pink Wire Core N/A 0V N/A N/A 0V
Grey Wire Core N/A Signal N/A N/A Signal
Storage Temperature Range N/A -30 to 85 ºC
Degree of Protection N/A IP 65
Installation Position N/A No Restriction
Note N/A Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided.
Additional Information N/A The different output signals (analogue current / voltage) enable connection to all HYDAC ELECTRONIC GmbH measurement and control devices as well as standard evaluation systems (e.g. PLC controls)

External set inputs for the analogue start point and end point offer an additional possibility of a customised adjustment. The HLT 2500-F1 is primarily used in stationary applications, especially when a partially integrated solution in hydraulic cylinders is not possible.
Core Products N/A
Division N/A ELECTRONICS
Product Group Family N/A POSITION SENSORS
Product N/A POSITION SENSOR