Part Number | 
                        
                            Model Code Description | 
                        
                            Sensing Temperature [Max] | 
                        
                            Input Probe Length | 
                        
                            Connection Type | 
                        
                            Output Signal | 
                        
                            Electrical Connection | 
                        
                            Core Products | 
                                                        
|---|---|---|---|---|---|---|---|
| 903381 | Model Code Description N/A ETS 4144-A-006-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 6 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male, 4 pole Binder series 714 M18 (Connector not supplied)  | 
                                Core Products | 
| 924505 | Model Code Description N/A ETS 4144-A-100-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 100 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male, 4 pole Binder series 714 M18 (Connector not supplied)  | 
                                Core Products | 
| 904522 | Model Code Description N/A ETS 4144-B-006-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 6 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 0 to 10 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male, 4 pole Binder series 714 M18 (Connector not supplied)  | 
                                Core Products | 
| 909119 | Model Code Description N/A ETS 4146-A-006-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 6 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male M12x1, 4 pole (Connector not supplied)  | 
                                Core Products | 
| 923732 | Model Code Description N/A ETS 4146-A-050-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 50 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male M12x1, 4 pole (Connector not supplied)  | 
                                Core Products | 
| 923605 | Model Code Description N/A ETS 4146-A-100-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 100 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male M12x1, 4 pole (Connector not supplied)  | 
                                Core Products | 
| 924609 | Model Code Description N/A ETS 4146-A-350-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 350 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male M12x1, 4 pole (Connector not supplied)  | 
                                Core Products | 
| 908335 | Model Code Description N/A ETS 4146-B-006-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 6 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 0 to 10 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male M12x1, 4 pole (Connector not supplied)  | 
                                Core Products | 
| 924225 | Model Code Description N/A ETS 4146-B-050-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 50 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 0 to 10 | 
                                    
                                        Electrical Connection                                                    
 N/A                                                        Male M12x1, 4 pole (Connector not supplied)  | 
                                Core Products | 
| 923457 | Model Code Description N/A ETS 4545-A-100-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 100 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | Electrical Connection N/A Male, 3 pole + PE, EN 175301-803 (DIN 43650) (connector supplied) | Core Products | 
| 923461 | Model Code Description N/A ETS 4546-A-050-000 | Sensing Temperature [Max] N/A -25 to 100 ºC-13 to 212 ºF | Input Probe Length N/A 50 mm | Connection Type N/A G1/4 A DIN 3852 (Male) | Output Signal N/A 4 to 20 | Electrical Connection N/A Male M12x1, 4 pole (Connector not supplied) | Core Products |